Part Number:AM3358
For a 24 MHz crystal, the only part available for AEC-Q200 and industrial temp has a 12pF load capacitance and 7pF max shunt capacitance. What is the recommended value for the C1 and C2? Note that Table 6-2 of the datasheet says for a shunt capacitance > 5pF, the minimum value of C1 and C2 is 18pF. Also note that CL = (C1*C2)/(C1+C2) + Cshunt = 16pF for C1=C2=18pF. CL = 13pF for C1 = C2 = 12pF, but this is well below the minimum 180pF recommended in Table 6-2.