Part Number:OMAP-L132
Hi Forum
As we have both Revision B and E (2.1 and 2.3) of the OMAP-L132 and our desire is to be able to use the same software releases for both, there is a question regarding applying the described patch in Advisory 2.3.24 (Boost ECC Data Error caused by NAND Boot Failure) as to whether that patch is safely applicable to both revisions?
The reason why this question arises here is that the failure (and thus a need for the patch) so far has only been discovered with Revision E and _NOT_ with Revision B.
The question is: Can we safely apply the AISGEN.exe version 1.11 and later that integrates the ECC Correct function to software running also on Revision B? Will this work the same?
An optional bonus follow up answer would be to address why there is a (seemingly?) difference between Rev B and Rev E in this regard.
Thanks in advance
Best regards,
Christopher Olofsson, Music Group Innovation Sweden.